Nominatim for Traffic Accident Database

From stgo
Revision as of 12:09, 4 March 2015 by StefanS (Talk | contribs)

Jump to: navigation, search

>> return Cedeus_IDE


Objective

Develop a script for automated geo-referencing of Chiles transit accident database.

Tools

Installing Nominatim

Setup of Nominatim VM

  1. copying basicubunutu1404.vdi file and renaming to nominatim.vdi
  2. creating the nominatim VM on CedeusDB (ip.18):
    • VBoxManage createvm --name nominatim --ostype Ubuntu_64 --register
    • VBoxManage modifyvm nominatim --memory 4096
    • VBoxManage modifyvm nominatim --cpus 4
    • VBoxManage modifyvm nominatim --nic1 nat
    • VBoxManage storagectl nominatim --name "SATA Controller" --add sata --controller IntelAhci
    • assign the (old) disk image a new uuid
      VBoxManage internalcommands sethduuid nominatim.vdi
    • attach the (old) disk image:
      VBoxManage storageattach "nominatim" --storagectl "SATA Controller" --port 0 --device 0 --type hdd --medium nominatim.vdi
    • VBoxManage storagectl nominatim --name "IDE Controller" --add ide --controller PIIX4
    • set the nat rules (ports):
      VBoxManage modifyvm nominatim --natpf1 "ssh,tcp,,20022,,22"
      VBoxManage modifyvm nominatim --natpf1 "apache,tcp,,20080,,80"
  3. optional - set VRDE port:
    • VBoxManage modifyvm nominatim --vrdeport 7761 (Note: 3389 is the default port anyway)
  4. check all settings with VBoxManage showvminfo nominatim
  5. start the VM
    VBoxHeadless -s nominatim --vrde on &
    the VM will listen on port 7761 - connect with GTKvncViewer to check
    • check if ssh connection works
  6. change the computers name in /etc/hosts and /etc/hostname
  7. restarting Apache gives the error message: "apache2: Could not reliably determine the server's fully qualified domain name, using 127.0.1.1 ..."
    => solve this by adding ServerName nominatim as the last line in /etc/apache2/apache2.conf file
  8. shut the VM down to resize the HDD if necessary
    • check the HDD size: VBoxManage showhdinfo nominatim.vdi returns:
UUID:           e148d758-00ac-4b60-a067-d5c97316069d
Parent UUID:    base</br>
State:          created
Type:           normal (base)
Location:       /home/ssteinig/nominatim.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       100000 MBytes
Size on disk:   6224 MBytes
In use by VMs:  nominatim (UUID: be795392-3786-4f3b-9714-a9445f91855d)
  • so I resized the disk to 200GB as, according to Nominatim infos the disk size for a full planet is 700GB
    VBoxManage modifyhd nominatim.vdi --resize 200000

Setup of Nominatim itself

  1. Install needed libraries
    • install PHP 5
    • install Postgres
    • install PEAR
    • install GCC, GIT, protbuf, wget, etc.
    • install Osmosis
    => see https://wiki.openstreetmap.org/wiki/Nominatim/Installation#Software
 apt-get install build-essential libxml2-dev libgeos-dev libpq-dev libbz2-dev libtool automake libproj-dev
 apt-get install gcc proj-bin libgeos-c1 git osmosis libgeos++-dev
 apt-get install php5 php-pear php5-pgsql php5-json php-db
 apt-get install postgresql postgis postgresql-contrib postgresql-9.1-postgis postgresql-server-dev-9.1
 apt-get install libprotobuf-c0-dev protobuf-c-compiler